Issue I438 [enhancement,particledef,resolved]
  Extend az/el angle range in particle definitions from +-180 to +-360
  degrees.

  Prior to 8.0.4-TEST15, azimuth and elevation angles were
  limited to the range +-180 degrees in ION, FLY, and FLY2 files.
  This sometimes made beam definitions in the -X direction more difficult
  as noted in the below report.

  As of 8.0.4-TEST15, the azimuth and elevation angle range has
  been extended to +-360 degrees.

  Reported by bernheim-20070920
    - http://www.simion.com/discuss/viewtopic?p=1876
    I would like to apply an uniform distribution from 179 and 181°
    for instance).

  Implemented in 8.0.4-TEST15.