SIMION®
The field and particle trajectory simulator
Industry standard charged particle optics software
Refine your design: model > simulate > view > analyze > program > optimize it.
About | Documentation | Community/Support | Downloads | Ordering

SIMION 8.0 Issues/Bugs/Enhancements

Filter issues by query:
Issue I454 [80,programming,defect,resolved]
  Prohibited access to reserved variables not triggering
  error, or error message identifies wrong variable name.

  Prior to 8.0.4-TEST19, no error was raised on a Lua segment
  attempting to write to a reserved variable not writable in any
  segment.  For example, this did not trigger an
  error in Release builds (but only an assert in Debug builds):

    function segment.accel_adjust() ion_dvoltsy_mm = 1 end

  This correctly triggers an error but the error message identifies
  the wrong variable name:

    function segment.initialize() ion_mm_per_grid_unit = 1 end

  Affects 8.0.0
  Resolved in 8.0.4-TEST19 (test case t2)

Any comments on this web page? (will be sent to IMI Adaptas SIMION Support)