Issue I457 [ion,enhancement,resolved]
  Charge weighting factor (CWF) permitted range changed to [0, 1E+30].

  Prior to 8.0.4-TEST20, the CWF for particles was restricted to the
  range [0.001, 100] (though it was still possible to use values
  outside this range as noted in Issue I456).

  As of 8.0.4-TEST20, this range has been modified to [0, 1E+30].

  The original rationale for this change is related to Issue I452,
  where the CWF is not used for charge repulsion but rather for data
  recording purposes.  Also, having a CWF of 0 could be useful for
  some circumstances, and changes made in Issue I453 now allow
  this.

  Requseted by igor-20071031

  Implemented in 8.0.4-TEST20