Issue I576 [faims,defect,resolved]
  Fixed FAIMS example pressure/temperature load_array coordinates.
  
  In \examples\faims\collision_sds.lua, for pressure and
  temperature arrays auto-loaded via load_array, the coordinates
  used to look up into the array were incorrectly in workbench
  (mm) units rather than absoluate array units (abs_gu).
  This problem affects "faims" since 2009-07-08.
  It does not affect the original "collision_sds" example.  It does
  not affect "faims" with pressure/temperature loaded via
  SDS.pressure or SDS.temperature, as in the included examples.

  Reported sa-2011-02-25.
  Resolved in faims-2011-02-25.